4. Additional Information
Specifications
Detector
Type Amorphous-Silicon Microbolometer
Spectral Response 7 to 14 microns
Thermal Performance
Time to Operation ~ 3 seconds
Contrast/Level Automatic (Electronic Image Control)
Image Touch-up Automatic (mechanical shutter)
Infrared Polarity White-Hot Black-Cold
Range to Detect Human
Activity
475 meters
Optics
Field of View 11
0
x 8
0
Focal Length 25 mm
Focus Range 1 meter to infinity
Video
Viewfinder Display Monochrome LCD
Viewfinder Brightness Adjustable (integral to on/off switch)
Auxiliary Video Out
Analog SMPTE-170 / NTSC
monochrome (output jack on rear)
Power
Power 2 AA Batteries
Operating Time
2 hrs (alkaline batteries); 6 hrs (lithium
batteries)
Auxiliary Power In 12Vdc (input jack on rear)